CSB HR1234W F2 12V 9Ah Valve Regulated Lead Acid AGM Battery
CSB HR1234W F2 12V 9Ah Valve Regulated Lead Acid AGM Battery
CSB HR1234W F2 12V 9Ah Valve Regulated Lead Acid AGM Battery
  • On sale!
  • New
CSB HR1234W F2 12V 9Ah Valve Regulated Lead Acid AGM Battery
CSB HR1234W F2 12V 9Ah Valve Regulated Lead Acid AGM Battery
CSB HR1234W F2 12V 9Ah Valve Regulated Lead Acid AGM Battery

12V 9Ah Sealed Lead Acid AGM Battery CSB HR1234WF2

R445.00
Tax included
In Stock at Create Energy

CSB HR1234WF2  Sealed Lead Acid Battery

5 Year Design Life

12V

9Ah

Please contact us for quantity discounts

Email: info@createenergy.co.za or telephone: +(27) 11 888 0410

Description

CSB HR1234WF2  Sealed Lead Acid Battery

VRLA AGM

5 Year Design Life

Maintenance Free

12V / 12 Volts

9Ah

12 V 34.0w/cell
HR 1234WF2 is specially designed for high efficient discharge application. Its characteristics are small volume, light weight and high discharge efficiency. It can be used for more than 260 cycles at 100% discharge in cycle service, up to 5 yeas in standby service.


Specification

Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 34W @ 15 minute-rate to 1.67V per cell @ 25°C (77°F)
Weight Approx. 2.50kg. (5.51lbs.)
Maximum Discharge current 100/130A (5sec.)
Internal Resistance Approx. Approx. 19mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 3.4A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25℃
Terminal F2-Faston Tab250
Container Material ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.

Constant Current Discharge Characteristics Unit: AMPERES (25°C,77°F)

F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 73.80 49.20 36.80 29.70 25.40 18.50 14.60 10.50 5.99 4.25
1.67V 65.80 44.80 34.40 28.20 24.20 17.80 14.10 10.30 5.86 4.15
1.70V 62.20 42.90 33.30 27.50 23.60 17.40 13.80 10.10 5.80 4.11
1.75V 56.30 39.80 31.60 26.20 22.70 16.80 13.50 9.90 5.69 4.05
1.80V 50.30 36.40 29.70 24.90 21.70 16.20 13.10 9.66 5.60 3.99
1.85V 43.30 32.90 27.60 23.50 20.70 15.60 12.70 9.39 5.50 3.92


Constant Power Discharge Characteristics Unit: WATTS (25°C,77°F)

F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V 706.00 506.00 395.00 328.00 286.00 211.00 169.00 124.00 71.70 50.80
1.67V 645.00 470.00 376.00 315.00 276.00 205.00 165.00 121.00 70.50 50.10
1.70V 618.00 454.00 366.00 308.00 270.00 202.00 163.00 120.00 70.00 49.60
1.75V 571.00 426.00 350.00 296.00 260.00 196.00 160.00 118.00 69.00 49.00
1.80V 524.00 400.00 333.00 285.00 250.00 191.00 156.00 116.00 68.10 48.30
1.85V 478.00 376.00 316.00 273.00 241.00 186.00 152.00 114.00 67.00 47.70

Product Details
CSBHR1234WF2

Data sheet

Battery Rated Capacity Amp-hour @20 Hr Rate to 1.6Volts per Cell9
Height (mm)100
Width (mm)65
Battery Rated Nominal Voltage12
Battery Mass (kg)2.7
Battery Terminal TypeF2 Faston Tab 250

Specific References

MPNHR1234WF2
Reviews(0)

Reviews

No customer reviews for the moment.

You need to be logged in or create an account to give your appreciation of a review.

This website use cookies to ensure you get the best experience on our website.Privacy Policy