CSB GP1272 F2 Terminal Valve Regulated Lead Acid VRLA AGM Battery
CSB GP1272 F2 Terminal Valve Regulated Lead Acid VRLA AGM Battery
CSB GP1272 F2 Terminal Valve Regulated Lead Acid VRLA AGM Battery
  • On sale!
  • New
CSB GP1272 F2 Terminal Valve Regulated Lead Acid VRLA AGM Battery
CSB GP1272 F2 Terminal Valve Regulated Lead Acid VRLA AGM Battery
CSB GP1272 F2 Terminal Valve Regulated Lead Acid VRLA AGM Battery

12V 7.2Ah Sealed Lead Acid AGM Battery CSB GP1272F2 F-2 Terminal

R315.00
Tax included
In Stock at Create Energy

CSB GP1272F2  Sealed Lead Acid Battery

5 Year Design Life

12V

7.2Ah

Please contact us for quantity discounts

Email: info@createenergy.co.za or telephone: +(27) 11 888 0410

Description

CSB GP1272F2 Sealed Lead Acid Battery

5 Year Design Life

Maintenance Free

12V / 12 Volts

7.2 Amp Hours / 7.2Ah

GP1272
12 V 7.2Ah

GP 1272 is a general purpose battery up to 5 years in standby service or more than 260 cycles at 100% discharge in cycle service. 


As with all CSB batteries, all are rechargeable, highly efficient, leak proof and maintenance free.

Specification

Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 7.2 Ah @ 20hr-rate to 1.75V per cell @ 25°C (77°F)
Weight (kg) Approx. 2.40kg. (5.29 lbs.)
Maximum Discharge current (A) 100A/130A (5sec.)
Internal Resistance Approx. Approx. 23mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 2.16A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25℃
Terminal F1-Faston Tab187
Container Material ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.


Constant Current Discharge Characteristics Unit: AMPERES (25°C,77°F)

F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 35.60 22.00 16.50 9.61 5.51 3.92 3.08 2.13 1.34 0.92 0.77 0.45
1.67V 33.10 21.00 15.90 9.36 5.41 3.85 3.02 2.08 1.31 0.90 0.76 0.44
1.70V 31.90 20.50 15.60 9.24 5.37 3.82 3.00 2.06 1.30 0.89 0.75 0.43
1.75V 29.60 19.60 15.10 9.03 5.30 3.77 2.96 2.02 1.27 0.88 0.74 0.42
1.80V 27.20 18.60 14.40 8.77 5.23 3.71 2.91 1.98 1.25 0.87 0.73 0.42
1.85V 24.50 17.40 13.70 8.44 5.14 3.66 2.87 1.95 1.22 0.86 0.71 0.40

Constant Power Discharge Characteristics Unit: WATTS (25°C,77°F)

F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 360.00 245.00 183.00 108.00 64.40 47.10 37.70 26.60 17.30 11.80 9.80 5.37
1.67V 340.00 235.00 177.00 106.00 63.60 46.40 37.10 26.30 17.00 11.60 9.68 5.27
1.70V 331.00 231.00 174.00 105.00 63.10 46.10 36.90 26.20 16.90 11.50 9.54 5.23
1.75V 313.00 222.00 170.00 103.00 62.40 45.50 36.40 25.90 16.70 11.40 9.47 5.15
1.80V 295.00 213.00 165.00 101.00 61.70 45.00 35.90 25.60 16.50 11.30 9.40 5.07
1.85V 276.00 202.00 158.00 99.00 60.80 44.30 35.40 25.20 16.30 11.20 9.29 4.99

Product Details
CSBGP1272F2

Data sheet

Battery Rated Capacity Amp-hour @20 Hr Rate to 1.6Volts per Cell7.2
Height (mm)100
Width (mm)65
Length (mm)151
Battery Rated Nominal Voltage12
Battery Mass (kg)2.4
Battery Terminal TypeF2 Faston Tab 250
Battery TechnologyAGM (Absobed Glass Mat) Sealed VRLA (Valve Regulated Lead Acid)

Specific References

MPNGP1272F2
Reviews(0)

Reviews

No customer reviews for the moment.

You need to be logged in or create an account to give your appreciation of a review.

This website use cookies to ensure you get the best experience on our website.Privacy Policy

Sign in

CREATE ENERGY

Your cart

There are no more items in your cart